pubmed:abstractText
Fifty apparently healthy individuals undergoing intravenous pyelography had electrocardiographic evaluation before, during, and after the examination. No patient had a major electrocardiographic change after contrast injection. Of the 7 patients with abnormal baseline electrocardiograms, all had a striking (greater than 40 beats per minute) rise in rate. The 43 patients with normal electrocardiograms had a small but significant rise in rate. No ischemic changes or major arrhythmias occurred. Although electrocardiographic aberrations were better correlated with baseline electrocardiograms than history or physical evaluation, our experience and a review of the literature confirms the safety of this examination in healthy people.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Jan
pubmed:issn
0090-4295
pubmed:author
pubmed:issnType
Print
pubmed:volume
9
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
88-90
pubmed:dateRevised
2007-11-15
pubmed:meshHeading
pubmed:year
1977
pubmed:articleTitle
Electrocardiographic changes with intravenous pyelography in healthy individuals.
pubmed:publicationType
Journal Article