pubmed:abstractText
The major problem associated with the long-term patency of the internal mammary artery graft is the early occurrence of stenosis usually at its distal anastomotic site; its management by balloon angioplasty has been associated with a high success rate. We report the case of an unsuccessful balloon angioplasty of an anastomotic stenosis of a left internal mammary artery graft that was successfully managed by stenting with one-half of a Palmaz-Schatz stent.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Jun
pubmed:issn
0098-6569
pubmed:author
pubmed:issnType
Print
pubmed:volume
32
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
157-61
pubmed:dateRevised
2004-11-17
pubmed:meshHeading
pubmed:year
1994
pubmed:articleTitle
Stenting the distal anastomotic site of the left internal mammary artery graft: a case report.
pubmed:affiliation
AHEPA General Hospital, University of Thessaloniki, Greece.
pubmed:publicationType
Journal Article, Case Reports