pubmed:abstractText |
A flameless atomic absorption method was developed for the determination of mercurial preservatives in biologicals. The assay was based on a quantitative determination of the mercury content of these preservatives. This method was used to analyze a variety of samples and yielded reproducible results with satisfactory recoveries. The procedure is presented in a simplified block diagram and described in detail relating its suitability for routine assay of large numbers of samples.
|
pubmed:commentsCorrections |
|
pubmed:language |
eng
|
pubmed:journal |
|
pubmed:citationSubset |
IM
|
pubmed:chemical |
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:issn |
0003-6919
|
pubmed:author |
|
pubmed:issnType |
Print
|
pubmed:volume |
27
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1094-7
|
pubmed:dateRevised |
2011-11-17
|
pubmed:meshHeading |
|
pubmed:year |
1974
|
pubmed:articleTitle |
Analysis of mercurial preservatives in bacterins, vaccines, and antisera by atomic absorption spectrophotometry.
|