Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:2801527rdf:typepubmed:Citationlld:pubmed
pubmed-article:2801527lifeskim:mentionsumls-concept:C2698872lld:lifeskim
pubmed-article:2801527lifeskim:mentionsumls-concept:C0026538lld:lifeskim
pubmed-article:2801527lifeskim:mentionsumls-concept:C0190010lld:lifeskim
pubmed-article:2801527lifeskim:mentionsumls-concept:C0871269lld:lifeskim
pubmed-article:2801527lifeskim:mentionsumls-concept:C0332282lld:lifeskim
pubmed-article:2801527lifeskim:mentionsumls-concept:C2699787lld:lifeskim
pubmed-article:2801527pubmed:issue12lld:pubmed
pubmed-article:2801527pubmed:dateCreated1989-10-28lld:pubmed
pubmed-article:2801527pubmed:abstractTextThe electrocardiographic, hemodynamic and surgical data of 30 patients who underwent a Fontan operation between 1977 and 1986 were retrospectively reviewed to identify the incidence and predictors of immediate and late postoperative arrhythmias and associated morbidity in long-term survivors. Of 4 patients who died less than 1 year after operation (mortality 13%), 1 death was related to an arrhythmia. Three patients were not in sinus rhythm before operation and were excluded from the statistical analysis that examined predictors of arrhythmias. The remaining 23 long-term survivors have been followed 6.3 +/- 2.6 years (mean +/- standard deviation) since surgery and all remain in New York Heart Association functional class I or II. Ten patients (43%) developed immediate postoperative arrhythmias (less than or equal to 30 days) whereas 11 (48%) had late arrhythmias. With up to 10.7 years of follow-up, the proportion of patients free from late arrhythmias continues to decline. Arrhythmias included bradyarrhythmias, atrial tachyarrhythmias, the tachy-brady syndrome and supraventricular ectopic activity. Immediate postoperative arrhythmias predicted late arrhythmias (p = 0.022). The preoperative electrocardiogram was the only variable useful in predicting both immediate and late postoperative arrhythmias. A more negative P-wave deflection in lead V1 (-2.4 +/- 0.7 vs -1.4 +/- 1.2 mV, p = 0.02) predicted patients with immediate postoperative arrhythmias, whereas both greater P-wave duration and a more negative deflection in this lead predicted late arrhythmias (103 +/- 14 vs 83 +/- 20 ms, p = 0.01, and -2.5 +/- 0.8 vs -1.3 +/- 1.0 mV, p = 0.005, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)lld:pubmed
pubmed-article:2801527pubmed:granthttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2801527pubmed:languageenglld:pubmed
pubmed-article:2801527pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2801527pubmed:citationSubsetAIMlld:pubmed
pubmed-article:2801527pubmed:statusMEDLINElld:pubmed
pubmed-article:2801527pubmed:monthOctlld:pubmed
pubmed-article:2801527pubmed:issn0002-9149lld:pubmed
pubmed-article:2801527pubmed:authorpubmed-author:HellenbrandW...lld:pubmed
pubmed-article:2801527pubmed:authorpubmed-author:KleinmanC SCSlld:pubmed
pubmed-article:2801527pubmed:authorpubmed-author:RosenfeldL...lld:pubmed
pubmed-article:2801527pubmed:authorpubmed-author:WeberH SHSlld:pubmed
pubmed-article:2801527pubmed:authorpubmed-author:PerlmutterR...lld:pubmed
pubmed-article:2801527pubmed:issnTypePrintlld:pubmed
pubmed-article:2801527pubmed:day1lld:pubmed
pubmed-article:2801527pubmed:volume64lld:pubmed
pubmed-article:2801527pubmed:ownerNLMlld:pubmed
pubmed-article:2801527pubmed:authorsCompleteYlld:pubmed
pubmed-article:2801527pubmed:pagination762-7lld:pubmed
pubmed-article:2801527pubmed:dateRevised2007-11-15lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:meshHeadingpubmed-meshheading:2801527-...lld:pubmed
pubmed-article:2801527pubmed:year1989lld:pubmed
pubmed-article:2801527pubmed:articleTitlePredictors of rhythm disturbances and subsequent morbidity after the Fontan operation.lld:pubmed
pubmed-article:2801527pubmed:affiliationSection of Pediatric Cardiology, Yale University School of Medicine, New Haven, Connecticut 06510.lld:pubmed
pubmed-article:2801527pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:2801527pubmed:publicationTypeResearch Support, U.S. Gov't, P.H.S.lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2801527lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2801527lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2801527lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2801527lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2801527lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2801527lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2801527lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2801527lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2801527lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2801527lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2801527lld:pubmed