Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
4
pubmed:dateCreated
2009-1-21
pubmed:abstractText
The TandemHeart percutaneous ventricular assist device (pVAD), which provides temporary circulatory support of the left ventricle, can be used in high-risk and hemodynamically unstable patients. The easily inserted TandemHeart provides cardiac support superior to that from the use of intra-aortic balloon pumps. Herein, we discuss TandemHeart implantation via end-to-side femoral arterial grafting in a cardiac patient whose sepsis and multiorgan failure were complicated by coagulopathy and thromboembolism. A 47-year-old woman, on intra-aortic balloon and intravenous inotropic support after an acute myocardial infarction and emergency coronary artery bypass grafting, was transferred to our institution via helicopter. She developed sepsis and multiorgan failure. Her condition was further complicated by coagulopathy and a left-lower-extremity thromboembolism. After 6 weeks of aggressive pharmacologic and intermittent intra-aortic balloon treatment, the patient developed cardiogenic shock and received a TandemHeart pVAD for short-term circulatory support. A GORE-TEX access graft, sewn end-to-side to the femoral artery because of the patient's leg ischemia and very small vessels, served as a conduit for the TandemHeart's femoral arterial inflow cannula. Her difficult circulatory, anatomic, and coagulopathic status stabilized after 2 weeks of TandemHeart support, and she was bridged to the long-term MicroMed DeBakey VAD Child in anticipation of heart transplantation. The case of our patient shows that high-risk patients who have experienced cardiogenic shock with multiorgan failure and coagulopathy can benefit from the TandemHeart pVAD as a bridge to other therapeutic options, even when creative approaches to treatment and to TandemHeart insertion are required.
pubmed:commentsCorrections
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:issn
1526-6702
pubmed:author
pubmed:issnType
Electronic
pubmed:volume
35
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
462-5
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
2008
pubmed:articleTitle
TandemHeart insertion via a femoral arterial GORE-TEX graft conduit in a high-risk patient.
pubmed:affiliation
Department of Surgery, Methodist DeBakey Heart Center, Baylor College of Medicine, Houston, Texas 77030, USA.
pubmed:publicationType
Journal Article, Case Reports