Source:http://linkedlifedata.com/resource/pubmed/id/18311592
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
5
|
pubmed:dateCreated |
2008-5-8
|
pubmed:abstractText |
Cardiac ultrasound imaging systems are limited in the noninvasive quantification of valvular regurgitation due to indirect measurements and inaccurate hemodynamic assumptions. We recently demonstrated that the principle of integration of backscattered acoustic Doppler power times velocity can be used for flow quantification in valvular regurgitation directly at the vena contracta of a regurgitant flow jet. We now aimed to accomplish implementation of automated Doppler power flow analysis software on a standard cardiac ultrasound system utilizing novel matrix-array transducer technology with detailed description of system requirements, components and software contributing to the system.
|
pubmed:grant | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:issn |
1569-5794
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
24
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
463-77
|
pubmed:meshHeading |
pubmed-meshheading:18311592-Adult,
pubmed-meshheading:18311592-Aged,
pubmed-meshheading:18311592-Automation,
pubmed-meshheading:18311592-Coronary Circulation,
pubmed-meshheading:18311592-Echocardiography, Doppler,
pubmed-meshheading:18311592-Equipment Design,
pubmed-meshheading:18311592-Female,
pubmed-meshheading:18311592-Humans,
pubmed-meshheading:18311592-Image Interpretation, Computer-Assisted,
pubmed-meshheading:18311592-Magnetic Resonance Imaging,
pubmed-meshheading:18311592-Male,
pubmed-meshheading:18311592-Middle Aged,
pubmed-meshheading:18311592-Mitral Valve Insufficiency,
pubmed-meshheading:18311592-Models, Cardiovascular,
pubmed-meshheading:18311592-Phantoms, Imaging,
pubmed-meshheading:18311592-Reproducibility of Results,
pubmed-meshheading:18311592-Severity of Illness Index,
pubmed-meshheading:18311592-Software,
pubmed-meshheading:18311592-Transducers
|
pubmed:year |
2008
|
pubmed:articleTitle |
Automated flow quantification in valvular heart disease based on backscattered Doppler power analysis: implementation on matrix-array ultrasound imaging systems.
|
pubmed:affiliation |
West German Heart Center Essen, Department of Cardiology, University of Duisburg-Essen, Hufelandstrasse 55, 45122 Essen, Germany. thomas.buck@uk-essen.de
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't,
Research Support, N.I.H., Extramural,
Validation Studies
|