Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
5
pubmed:dateCreated
2008-5-8
pubmed:abstractText
Cardiac ultrasound imaging systems are limited in the noninvasive quantification of valvular regurgitation due to indirect measurements and inaccurate hemodynamic assumptions. We recently demonstrated that the principle of integration of backscattered acoustic Doppler power times velocity can be used for flow quantification in valvular regurgitation directly at the vena contracta of a regurgitant flow jet. We now aimed to accomplish implementation of automated Doppler power flow analysis software on a standard cardiac ultrasound system utilizing novel matrix-array transducer technology with detailed description of system requirements, components and software contributing to the system.
pubmed:grant
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Jun
pubmed:issn
1569-5794
pubmed:author
pubmed:issnType
Print
pubmed:volume
24
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
463-77
pubmed:meshHeading
pubmed-meshheading:18311592-Adult, pubmed-meshheading:18311592-Aged, pubmed-meshheading:18311592-Automation, pubmed-meshheading:18311592-Coronary Circulation, pubmed-meshheading:18311592-Echocardiography, Doppler, pubmed-meshheading:18311592-Equipment Design, pubmed-meshheading:18311592-Female, pubmed-meshheading:18311592-Humans, pubmed-meshheading:18311592-Image Interpretation, Computer-Assisted, pubmed-meshheading:18311592-Magnetic Resonance Imaging, pubmed-meshheading:18311592-Male, pubmed-meshheading:18311592-Middle Aged, pubmed-meshheading:18311592-Mitral Valve Insufficiency, pubmed-meshheading:18311592-Models, Cardiovascular, pubmed-meshheading:18311592-Phantoms, Imaging, pubmed-meshheading:18311592-Reproducibility of Results, pubmed-meshheading:18311592-Severity of Illness Index, pubmed-meshheading:18311592-Software, pubmed-meshheading:18311592-Transducers
pubmed:year
2008
pubmed:articleTitle
Automated flow quantification in valvular heart disease based on backscattered Doppler power analysis: implementation on matrix-array ultrasound imaging systems.
pubmed:affiliation
West German Heart Center Essen, Department of Cardiology, University of Duisburg-Essen, Hufelandstrasse 55, 45122 Essen, Germany. thomas.buck@uk-essen.de
pubmed:publicationType
Journal Article, Research Support, Non-U.S. Gov't, Research Support, N.I.H., Extramural, Validation Studies