We sought to investigate the use of a new parameter, the projected effective orifice area (EOAproj) at normal transvalvular flow rate (250 mL/s), to better differentiate between truly severe (TS) and pseudo-severe (PS) aortic stenosis (AS) during dobutamine stress echocardiography (DSE). Changes in various parameters of stenosis severity have been used to differentiate between TS and PS AS during DSE. However, the magnitude of these changes lacks standardization because they are dependent on the variable magnitude of the transvalvular flow change occurring during DSE.
pubmed:commentsCorrections
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:status
MEDLINE
pubmed:month
Feb
pubmed:issn
1524-4539
pubmed:author
pubmed:issnType
Electronic
pubmed:day
7
pubmed:volume
113
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
711-21
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed:year
2006
pubmed:articleTitle
Projected valve area at normal flow rate improves the assessment of stenosis severity in patients with low-flow, low-gradient aortic stenosis: the multicenter TOPAS (Truly or Pseudo-Severe Aortic Stenosis) study.
pubmed:affiliation
Research Center of Laval Hospital/Quebec Heart Institute, Laval University, Sainte-Foy, Quebec, Canada.
pubmed:publicationType
Journal Article, Clinical Trial, Research Support, Non-U.S. Gov't, Multicenter Study