Source:http://linkedlifedata.com/resource/pubmed/id/15135091
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
2004-5-11
|
pubmed:abstractText |
A sensitive, rapid and selective liquid chromatography-positive electrospray ionization tandem mass spectrometry (LC-(ESI+)-MS-MS) method has been developed and validated for the simultaneous quantification of beclomethasone dipropionate (BDP) and its active metabolite, beclomethasone 17-monopropionate (17-BMP) in rat plasma and different tissues using fluticasone propionate (FP) as the internal standard. The method was validated over a linear range from 0.05 to 5 ng/ml for both analytes. A solid-phase extraction procedure was used for plasma samples and a liquid-liquid extraction procedure for tissues samples (lung, liver and kidney). The between-day and within-day coefficients of variation for all compounds were </= 20% at the concentrations of lower limit of quantification (LLOQ) and </= 15% at other quality control concentrations. The same method was also partially validated for human plasma. The utility of this assay was demonstrated by monitoring BDP and 17-BMP plasma and tissue concentrations in an animal study designed for evaluation of pulmonary targeting after intratracheal administration of BDP dry powder.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:issn |
1570-0232
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
15
|
pubmed:volume |
805
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
203-10
|
pubmed:meshHeading |
pubmed-meshheading:15135091-Animals,
pubmed-meshheading:15135091-Anti-Inflammatory Agents,
pubmed-meshheading:15135091-Beclomethasone,
pubmed-meshheading:15135091-Chromatography, Liquid,
pubmed-meshheading:15135091-Humans,
pubmed-meshheading:15135091-Rats,
pubmed-meshheading:15135091-Spectrometry, Mass, Electrospray Ionization
|
pubmed:year |
2004
|
pubmed:articleTitle |
Simultaneous quantification of beclomethasone dipropionate and its metabolite, beclomethasone 17-monopropionate in rat and human plasma and different rat tissues by liquid chromatography-positive electrospray ionization tandem mass spectrometry.
|
pubmed:affiliation |
Department of Pharmaceutics, College of Pharmacy, University of Florida, Gainesville, FL 32610, USA.
|
pubmed:publicationType |
Journal Article,
Validation Studies
|