Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
1-9
pubmed:dateCreated
2004-3-29
pubmed:abstractText
This paper deals with a quantitative study of the conversion of a Lamb wave at the bevelled edge of a plate. A harmonic wave (successively the A1 and S0 Lamb modes) is generated using a wedge. The normal displacements at the surface of the plate are measured with a laser vibrometer and used to compute an energy evaluation. In order to determine a good mean value of incident and reflected wave amplitudes, the signals are isolated by a Fourier treatment. Then, the energy flow repartition among the converted modes is computed in both cases and for different values of the bevel angle.
pubmed:language
eng
pubmed:journal
pubmed:status
PubMed-not-MEDLINE
pubmed:month
Apr
pubmed:issn
0041-624X
pubmed:author
pubmed:issnType
Print
pubmed:volume
42
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
377-81
pubmed:dateRevised
2009-11-11
pubmed:year
2004
pubmed:articleTitle
Experimental study and signal analysis in the Lamb wave conversion at a bevelled edge.
pubmed:affiliation
Laboratoire d'Acoustique Ultrasonore et d'Electronique, LAUE-CNRS (UMR 6068), Université du Havre, Place Robert Schuman, BP 4006, 76610 Le Havre, France. wilkie@iut.univ-lehavre.fr
pubmed:publicationType
Journal Article