Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
5
pubmed:dateCreated
2001-12-4
pubmed:abstractText
This study was conducted to document test-retest reliability of hearing thresholds using our computer-automated tinnitus matching technique and Etymotic ER-4B Canal Phone insert earphones. The research design involved repeated threshold measurements both within and between sessions, and testing to evaluate the potential effect of eartip removal and reinsertion. Twenty normal-hearing subjects were evaluated over two testing sessions with the use of a fully automated protocol for determining thresholds with 1-dB precision. Thresholds were first obtained at 0.5-16.0 kHz, in one-third octave frequency steps (16 test frequencies). The octave frequencies were then retested, first without removing the eartips, then after eartip removal and replacement. Responses between sessions differed by an average of 2.5 dB across all 16 test frequencies, and 91.5 percent of the repeated thresholds varied within +/-5 dB (98.1 percent within +/-10 dB). Reliability of within-sessions thresholds was also good, and there was no effect of eartip removal and replacement.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:issn
0748-7711
pubmed:author
pubmed:issnType
Print
pubmed:volume
38
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
567-81
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed:articleTitle
Reliability of hearing thresholds: computer-automated testing with ER-4B Canal Phone earphones.
pubmed:affiliation
National VA Rehabilitation Research and Development Center for Rehabilitative Auditory Research, Portland VA Medical Center, OR 97207, USA. henryj@ohsu.edu
pubmed:publicationType
Journal Article, Research Support, U.S. Gov't, Non-P.H.S.